Brand Name : KACISE
Model Number : KGD-GAS-211
Certification : CE
Place of Origin : CHINA
MOQ : 1PCS
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Detected Gas Object : NMP (n-methyl-2-pyrrolidone)
Concentration Display : 7-segment LED (4 digits)
Detection Range : 0-100%LEL
Display Resolution : 0.5%LEL
Sampling Method : Differential pressure intake inside the furnace
Alarm Set Value : 15%LEL~50%LEL (default 25%LEL, can be set)
NMP Gas Leak Alarm KGD-GAS-211
Product Introduction
The NMP Gas Leak Alarm KGD-GAS-211 is a high-performance NMP gas leak alarm independently developed by KACISE based on the Non-Dispersive Infrared (NDIR) principle. It is suitable for detecting the gas concentration in the center of drying equipment and exhaust pipes. The sampling instrument body and the display part adopt an integrated explosion-proof structural design, which is convenient for installation and disassembly. Meanwhile, this instrument has the characteristics of automatic calibration, long-term maintenance-free operation, and a long service life. It has functions such as industrial 4-20mA current output, RS485 external communication, and concentration over-limit alarm output, and can be applied to complex and harsh high-temperature industrial environments.
Product Features
Technical Parameters
Detected Gas Object | NMP (n-methyl-2-pyrrolidone) |
Concentration Display | 7-segment LED (4 digits) |
Detection Range | 0-100%LEL |
Display Resolution | 0.5%LEL |
Sampling Method | Differential pressure intake inside the furnace |
Alarm Set Value | 15%LEL~50%LEL (default 25%LEL, can be set) |
External Output | Gas concentration signal/alarm contact |
Communication Method | DC4~20mA (resistive load below 300Ω), RS485 (default baud rate of 9600) |
Alarm Accuracy | ±5%LEL@15%LEL~50%LEL |
Alarm Delay | T90<30s@15%LEL~50%LEL |
Alarm Contact Capacity | 250VAC0.2A/30VDC1.5A (impedance load) |
Alarm Action | Automatic reset |
Operating Voltage | 24VDC±10% |
Average Operating Current | Average operating current < 1.0A (@25℃, 24VDC) |
Warm-up Time | ≤30min |
Operating Temperature | Temperature of the measured gas: 0~160℃ (usually); Temperature of the instrument head: 0~60℃ (usually) |
Operating Humidity | Less than 95%RH (no condensation) |
Service Life | 10 years |
Structure | Direct insertion into the furnace |
Explosion-proof Structure | Explosion-proof structure |
Explosion-proof Rating | ExdbIICT3Gb |
Overall Dimensions/Weight | 418mm178mm110mm/Approximately 6kg |
![]() |