Signal Transmission : ABUS four - wire bus, TBUS two - wire bus
Operating Voltage : AC220V ± 15%/50HZ
Alarm Threshold and Alarm Method : High - limit alarm
Communication Distance : ≤ 1000m (RVSP1.5mm²)
Detected Gases and Bus Capacity : Combustible gases, toxic and hazardous gases, configured with 1/2/4/8 points
Power Consumption : ≤ 10W (excluding detector)
KAN121 Gas Alarm Controller
Product Introduction
It has two sets of built - in passive relay contact outputs, which can directly control solenoid valves and AC fans (AC220V) with a power less than 1100W. It allows for remote correction of detector sensitivity and zero - point adjustment, eliminating the need for on - site calibration using large - scale gas distribution equipment. It is equipped with an automatic fault detection function and can indicate the location and type of the fault. It can store 2000 historical records in different categories. It is optional to carry out the transformation work for a three - wire system. The system has a reserved communication interface, facilitating networking with third - party control systems.
Product Description
Signal Transmission | Operating Voltage | Alarm Threshold and Alarm Method | Communication Distance |
ABUS four - wire bus, TBUS two - wire bus | AC220V ± 15%/50HZ | High - limit alarm Low - limit alarm Audible and visual alarm | ≤ 1000m (RVSP1.5mm²) |
Detected Gases and Bus Capacity | Power Consumption | Control Output | Display Method |
Combustible gases, toxic and hazardous gases, configured with 1/2/4/8 points | ≤ 10W (excluding detector) | Two - way programmable linkage output (contact capacity 5A/DC24V or 5A/AC220V), Pulse output: 500mS break, Continuous output: Switch - quantity output | 3.2 - inch 128×64 pixel dot - matrix liquid crystal LED backlit display screen, using Chinese + icon display |
Under - voltage Alarm Point and Indication Error | Working Environment | Detection Unit | Optional Accessories |
165V ± 10V, ± 5%FS | Temperature: 0°C - 40°C, Humidity: ≤ 93%RH | %LEL, PPM, %VOL mg/m³, °C, %RH | Backup battery: 2 pieces of DC12V/1.3AH storage batteries, ASD - MK5215 isolated RS485 converter (Optional modules below) LORA, Ethernet, WIFI, NB |
![]() |