Brand Name : Kacise

Model Number : KCS571

Place of Origin : shanxi xi'an

MOQ : 1

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 1000 Pieces per Week

Delivery Time : 5 work days

Packaging Details : each unit has indicidual box and all boxes are packed in standard packages or customers requests available

Storage Temperature : -20-80℃

Operating Temperature : -20-60℃

Operating Humidity : 0-90%RH

Work Pressure : 0.8-1.2 atm

Supply Voltage : 5-5.5V

Maximum Operating Current : 120-150mA

Detection Range : 100% vol can be customized ppm

Contact Now

KCS571

Infrared CO2 Gas Sensor Module

1. Brief Introduction

SW711 is a gas sensor based on the principle of NDIR infrared absorption, suitable for testing the gas concentration of various heteronuclear molecules in industrial applications.

SW711 adopts a patented optical cavity, imported light source and dual-channel detector to achieve dual optical path reference compensation in space. SW711 has good selectivity, no oxygen dependence and long life.

The SW711 has UART, 4 to 20mA outputs, 485 outputs, etc., and provides customers with a manually calibrated MCDL pin. It is convenient for customers to use outdoor free-flowing clean air to calibrate the sensor module relative to zero.

SW711 adopts diffusion ventilation method, and the response time is less than 30 seconds.

The SW711 is available in a variety of packages that can be customized to meet customer needs. There are three common packages: package one, package two (six pins 4-20mA), package three (seven pins 485 interface), of which package two and package three are the same size.

2. KCS571 size block diagram

Package one

Package 2 (6-pin 4-20mA) Package 3 (7-pin 4 85 connectors).

3. KCS571 Technical Parameters

parameter symbol minimum Typical values maximum unit
Storage Temperature Tstg -20 - 80 °C
Operating Temperature TA -20 60 °C
Operating Humidity HA 0 90 % RH
Work Pressure PA 0.8 1.2 atm
Supply Voltage Vs 5 5 5.5 V
Maximum Operating Current Imax 120 150 mA
Detection Range 200 50000 100% vol can be customized ppm
Measurement accuracy - ± 50ppm or ±3% true value ± 300ppm± 3% true ppm
T90 diffusion - 30 60 second
repeatability zero <±50 ppm
50% FS - <±2% of the measured value -
life span 3 5 10 year

5.Installation instructions

The sensor mounting thread dimensions refer to the block diagram.

6.Matters that should be paid attention to in maintenance

The sensor should be calibrated regularly, it is recommended that it be no more than 3 months, and calibration is not required on the long-term operation side if automatic calibration is turned on

Do not use the sensor for a long time in an environment with a high density of dust

Please use the sensor within the range of the sensor's power supply

7.Ordering instructions

In order to be able to purchase the specific specifications required, please provide the following information

1) Sensor name, 2) Sensor range 3) Sensor measurement accuracy and output mode, etc

For example, SW711, 50000ppm, 4-20mA output

8.Ordering Information

Order Information Selection Form
products power supply Cable length Signal output
KCS571 Infrared CO2 Gas Sensor Module
12VDC Power supply is 12VDC (default)
220V/110VAC The power supply is 220/110VAC
Cable length
XXm The default is 5 meters, the maximum is 500 meters
4-20mA 4-20mA output without RS485 output
RS485 RS485 output, without 4-20mA output by default
ARS485 4-20mA output with RS485 output
Modbus-RTU The protocol for the RS485 output is Analog-to-Digital Bus-RTU (default)
Modbus-ASC The protocol for RS485 output is Modbus-RTU
KCS571 DC12V 5 meters RS485

9.Precautions

1 In environments with EMC issues, shielded cables must be used.

2 When the module is cold started, the warm-up time should not be less than 2 minutes.

3 The sensor should be calibrated regularly, not more than 3 months is recommended.

4 Do not use the sensor for a long time in a dusty environment.

5 Please pay attention to the wiring of the positive and negative terminals of the power supply and the signal output terminals. Do not connect backwards.

6 High concentrations of chemical contamination can lead to the destruction of the sensor polymer layer, therefore, the product should be stored and used away from the source of chemical contamination.

7 Please refer to the relevant national product installation standards for the installation process.

Contact Details

URL: www.kacise.com

Tel: +86-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, High-tech Zone, Xi'an, Shaanxi Province

Appendix

Shorthand Full name
VOL 1% VOL refers to 1% of the volume of a particular gas in air.
PPM 1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2 Oxygen molecules
LCD LCD display
RS485 Asynchronous serial port 485
DC direct current
AC Communication
PVC polyvinyl chloride


Product Tags:

Ir CO2 Gas Detector Sensor

      

100% Vol CO2 Gas Detector Sensor

      

100% Vol CO2 Detector Sensor

      
Best 100% Vol Ir CO2 Gas Detector Sensor Module Heteronuclear Molecules wholesale

100% Vol Ir CO2 Gas Detector Sensor Module Heteronuclear Molecules Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)